![•Periodically](/images/new-backgrounds/65657/6565723x1.webp)
EN 12/ CLEANING YOUR APPLIANCE
•Periodically
Every 3 or 4 months, in order to remove any deposits, run a special maintenance programme, with- out any items in the machine, using a special dishwasher cleaning product.
Important :
Keep this product out of children’s reach.
•If not using your dishwasher for a prolonged period:
Clean your dishwasher completely and then unplug it from the electricity supply and close the water tap. Protect your machine from potential frost.
Advice :
Do not use abrasive powders, metal sponges and
If you are moving house, run a soaking programme first of all, in order to avoid any water escaping.
EN 13/ IF OPERATING ABNORMALITIES OCCUR
• SUMMARY OF THE FAULTS
Flashing LED(s) | for models without a display | Flashing LED(s) | |||||
|
|
|
|
|
| ||
| d01 | : water supply fault (tap) | d07 | : overflow / |
| ||
|
|
|
|
|
| ||
| d02 | : draining fault | d08 | : sprinkling distribution fault |
| ||
|
|
|
|
| |||
| d03 | : heating fault | d11 : pressure sensor fault |
| |||
|
|
|
|
|
|
| |
| d04 : temperature fault | d12 | : filling fault (water inlet |
| |||
|
| detection system) |
|
| |||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
| d05 | : faulty motor | d13 | : faulty heating |
|
| |
|
|
|
|
|
| ||
| d06 | : faulty motor | d14 : installation fault : (incorrect drainage |
| |||
| connection or inadequate flow rate and tap). |
| |||||
|
|
|
|
| |||
|
|
|
|
|
|
|
|
Tip:
If one of the above faults occurs and you need to call a repair man, remember to tell him the message displayed (d01, d02..) as this information will help him.
• BEFORE CALLING FOR SERVICE
Problem | Possible Causes | What to do? |
|
|
|
The door falls heavily when | - Door springs not tensioned | - Tighten the two tensioning |
opened (integratable model) | enough to compensate for the | screws accessible in the bot- |
| weight of the panel. | tom section above the front |
|
| feet. |
|
|
|
The door does not stay horizontal | - Door springs tensioned too | - Loosen the two tensioning |
when open or returns too quickly | much. | screws accessible in the bot- |
(integratable model) |
| tom section above the front |
|
| feet. |
| - No wooden panel. | - Fit a temporary wooden panel |
|
| on the appliance and adjust |
|
| the springs. |
|
|
|
The door catches when closing | - Appliance not stable | - Adjust the feet. |
| - Door not centred on the tub | - |
|
| rear feet. |
|
|
|
The upper basket does not stay | - Poor manipulation (the basket | - Act more progressively (see |
in the high position | is being pulled upwards too | instructions), one side and |
| quickly) | then the other. |
|
|
|
Small leak around or under the | - Leak from the tap. | - Check that a seal is fitted and |
appliance (move the appliance | - Leak from the appliance. | retighten the nut. |
to locate the leak) | - Close the water tap and call a | |
| (Cf. table fault d07). | technician. |
|
| |
|
|
|
Small leak at the door | - Appliance not stable or not level | - Adjust the feet. |
| - Door not centred on the tub. | - |
|
| feet. |
|
|
|
22 | 23 |