Miele CVA 2660 installation instructions Cleaning and care, Open the appliance door

Models: CVA 2660

1 68
Download 68 pages 33.61 Kb
Page 41
Image 41
Manual background

Cleaning and care

The right display goes dark and the appliance is now lowering the perforator.

Remove capsule plate and change the capsule hopper

￿Open the appliance door.

￿Pull out the capsule plate.

￿Do not reach up into the perforator opening. Danger of injury!

￿Pull the rubber disc top, down and out.

￿Screw the new perforator firmly into the unit. The spring and ball bearing must be inserted in the perforator opening so that the ball bearing is on top.

￿Insert the rubber disc from the bottom up (with the funnel pointing downwards).

￿Insert the capsule plate and close the door.

￿Insert the tool for removing the perforator up into the unit, ￿. Turn it to the left, ￿, to loosen and remove the perforator.