Miele DA210-3 installation instructions Air extraction

Models: DA210-3

1 36
Download 36 pages 10.77 Kb
Page 32
Image 32
Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connect- ing an exhaust hood vent to an exist- ing, inactive chimney or vent flue.

Air extraction

Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connect- ing an exhaust hood vent to an exist- ing, inactive chimney or vent flue.

Ductwork with a diameter of less than 6" (150 mm) should only be used when absolutely necessary. As duct diameter decreases, the hood’s performance and sound levels will be affected.

Important:

If the ductwork runs through rooms, ceilings, garages, etc. where tempera- ture variations exist, it may need to be insulated to reduce condensation. In some cases, a condensate trap may also be required to collect and evapo- rate any condensate which may occur.

When installing a condensate trap, ensure that it is positioned vertically and if possible directly above the ex- haust outlet.

32

Page 32
Image 32
Miele DA210-3 installation instructions Air extraction