Electrical connection
Important
The ventilation system must be hard wired as follows:
|
|
| Downdraft |
|
|
| wiring |
(ground)GND | (neutral)N | L1(live) | |
|
|
| |
|
|
| connectors |
Groundscrews | WHITE | BLACK | Motor wiring |
|
|
| |
dai2748
Black wire: . . . . . . . connect to L1 (live)
White wire: . . . . . connect to N (neutral)
. . . . . . . . . . . . . . . . . . . . . . . . . (ground)
The remote blower must be connected to the ventilation system wiring as described in the manual for DA 6480/6490.
Close the terminal box.
Close the cover of the external blower.
Turn the power supply back on.
Maximum load . . . . . . . . . . . . . . . 210 W Voltage . . . . . . . . . . . . . . . . . . . . . 120 V Frequency . . . . . . . . . . . . . . . . . . 60 Hz Circuit Rating . . . . . . . . . . . . . . . . . 15 A