Miele F 311 i-6 Installation, Location, Ventilation, Before installation, Climate range

Models: F 311 i-6

1 36
Download 36 pages 61.46 Kb
Page 30
Image 30
Installation

Installation

This appliance must be built in, otherwise it could tip up.

Location

The appliance should be installed in a dry well ventilated room.

The room temperature should not go above or below the climate range for which the appliance is designed. The higher the ambient temperature of the room the more energy the appliance requires to operate. It should not be installed where it is exposed to direct sunlight or directly adjacent to a heat-producing appliance such as an oven or a radiator.

Climate range

The appliance is designed for a particular climate range (ambient room temperature), and should not be used outside this range. The climate range of this appliance is stated on the data plate inside the appliance.

Climate range

Ambient room

 

temperature

 

 

SN, N

to +32 °C

ST

to +38 °C

T

to +43 °C

 

 

The appliance will function perfectly down to a temperature of +5 °C.

Ventilation

Air at the rear of the appliance gets warm. The appliance housing unit must be constructed to allow sufficient space for ventilation. Miele kitchen units are designed to provide this ventilation.

A ventilation gap of at least 50 mm depth must be allowed for behind the appliance for air to circulate.

The air inlet to the appliance is via the plinth in the housing unit.

The cross section of the air inlet and outlet must be at least 200 cm2 to ensure that air can circulate without hinderance. Otherwise the appliance has to work too hard resulting in an increase in electricity consumption and damage to the compressor.

The air inlet and outlet must not be covered or blocked in any way. They should be dusted on a regular basis.

Before installation

^Before installation remove the sealing strip etc. from the outside of the appliance and take any accessories out of the inside of the appliance.

^Remove any cable clips from the rear of the appliance.

^Check that all parts at the rear of the appliance are unhindered.

30

Page 30
Image 30
Miele F 311 i-6 installation instructions Installation, Location, Ventilation, Before installation, Climate range