All electrical work must be carried
out by a qualified electrician in
accordance with local and national
safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer can
not be held responsible for
unauthorized work.
^For technical data see the data plate
or wiring diagram supplied.
The machine must only be operated
with the voltage, frequency and fusing
shown on the data plate.
The data plate is on the cover plate
behind the service panel of the unclean
side.
The wiring diagram is secured to the
inner side of the service panel.
This unit is convertible for use with
steam or electric heating.
Hook up requirements are as follows:
1. Electric heat only:
208 V 3 phase 60 HZ 60 amp
2. Steam heat only:
without drying option
208 V 3 phase 60 HZ 20 amp
with drying option
208 V 3 phase 60 HZ 30 amp

WARNING:

THIS APPLIANCE MUST BE

GROUNDED

Electrical connection
41