Miele KM 2030, KM 2050 manual Burner performance

Models: KM 2050 KM 2030

1 44
Download 44 pages 18.22 Kb
Page 37
Image 37
Burner performance

Burner performance

Rated load at high setting

Burner

Type of gas

KM 2030

KM 2050

 

 

BTU/hr

kW

BTU/hr

kW

Small burner

Natural gas (NG)

3500

1,00

3500

1,00

 

Liquid gas (LP)

3500

1,00

3500

1,00

Regular burner

Natural gas (NG)

6200

1,80

6200

1,80

 

Liquid gas (LP)

5800

1,70

5800

1,70

Power burner

Natural gas (NG)

-

-

8900

2,60

 

Liquid gas (LP)

-

-

8900

2,60

Wok

Natural gas (NG)

12000

3,50

12000

3,50

 

Liquid gas (LP)

11000

3,20

11000

3,20

 

 

 

 

 

 

Total

Natural gas (NG)

27900

8,10

36800

10,70

 

Liquid gas (LP)

26100

7,60

35000

10,20

Rated load at low setting

 

 

 

 

 

 

 

 

 

Burner

Type of gas

KM 2030 / KM 2050

 

 

 

BTU/h

 

kW

 

Small burner

Natural gas (NG)

850

 

0,25

 

 

Liquid gas (LP)

850

 

0,25

 

Regular burner

Natural gas (NG)

1200

 

0,35

 

 

Liquid gas (LP)

1200

 

0,35

 

Power burner

Natural gas (NG)

1700

 

0,50

 

 

Liquid gas (LP)

2000

 

0,60

 

Wok

Natural gas (NG)

3700

 

1,10

 

 

Liquid gas (LP)

3700

 

1,10

 

37

Page 37
Image 37
Miele KM 2030, KM 2050 manual Burner performance