Optimum temperature and air quality
Temperature display
During normal operating, the temperature displays indicate the temperatures inside the unit.
The temperature display will flash if:
–a different temperature is being set,
–the temperature in one section deviates from the set temperature by more than 5 °.
Setting the temperature display brightness
The factory set brightness of the temperature display is set at the lowest setting.
To adjust the brightness of the temperature display (the temperature displays adjust together):
Press and hold the constant humidity button for approx. 5 seconds.
The indicator light will flash, and the temperature display for the bottom zone (right display) flashes .
Press and hold + or - for the upper zone (left display) until ^ appears in the display.
Press the constant humidity button again.
^appears in the display.
The display brightness cannot be set using the + / - buttons for the upper
temperature zone. You can choose a brightness level from 1 to 5.
1 :dimmest setting
5 :brightest setting
To save the setting, press the constant humidity button.
To exit the settings mode, press the On/Off button. Otherwise, the electronics will automatically return to normal mode after approx. 2 minutes.
12