In areas with a tropical climate (over 100°F/38°C and more than 70% air humidity) the wine cooler must only be operated in air conditioned locations. Otherwise the function of the machine cannot be guaranteed.

This appliance is top-heavy and must be secured to prevent the possibility of tipping forward.

Location

The appliance should be installed in a dry, well-ventilated room.

The installation location should not be exposed to direct sunlight, nor near a heat source, such as an oven, radiator, etc.

The ambient temperature should not drop below 55 °F (13 °C) or rise above 110 °F (43 °C), otherwise malfunctions may occur.

Ventilation

The air at the back of the appliance gets warm. The appliance housing unit must be constructed to allow sufficient space for ventilation.

The air intake and outlet must not be blocked or covered in any way. They also need to be dusted/cleaned on a regular basis.

Before installation

￿Remove all accessories from the appliance.

￿Remove any cable clips from the rear of the appliance.

￿Check that all parts at the back of the appliance are not blocked.