To change the exhaust connection from the rear of the machine to the left side of the machine

^Remove the vent socket from the rear exhaust port by inserting a thin screwdriver into the slot by the retain- ing clip. Press the clip gently up- wards and at the same time turn the connector counterclockwise.

^Press the retaining clip of the cap covering the left exhaust port up- wards, turn it counterclockwise.

^Secure the connector into the side port by pressing it in and turning it clockwise.

^Seal the rear exhaust port with the cap.