Miele T 1576 operating instructions Example, Result

Models: T 1576

1 40
Download 40 pages 2.97 Kb
Page 32
Image 32

INSTALLATION INSTRUCTIONS

Flexible metal ducting has been used for the following example. Other duct types may require additional duct length (see Table 1.)

Example:

Vent connection left . . . . . . . 39" (1.0 m) Length (L). . . . . . . . . . . . . . . 47" (1.2 m) Lower radius (R). . . . . . . . . . 19" (0.5 m) Height (H). . . . . . . . . . . . . . . 39" (1.0 m) Upper radius (R) . . . . . . . . . 19" (0.5 m) Wall pipe w/ grill frame . . . . 149" (3.8 m)

Effective duct length . . . . 312" (8.00 m)

Result:

A duct diameter of 4" (100 mm) is ade- quate since the effective length is less than 66 ft. (20 m) as specified in Table 2.

28

Page 32
Image 32
Miele T 1576 operating instructions Example, Result