Problem Possible cause Remedy
Water leaks from the
dryer after the
condenser unit has
been cleaned.
The inner cover of the
condenser unit has not
been locked properly
and/or the condenser
unit has not been
positioned correctly.
Fluff has collected in
the condenser unit
housing.
Ensure that the
condenser unit is
positioned correctly
and lock the inner
cover.
Check the rubber
seals.
Use a cloth to remove
any visible fluff from the
inside of the condenser
unit housing.
The programme does
not start.
No obvious cause. Is the dryer switched
on?
Is the plug correctly
inserted into the socket
and switched on?
Is the door closed
properly?
Has the fuse or circuit
breaker tripped?
Power cut. A programme which was running previously will
continue automatically when power is restored to the
tumble dryer as long as the Cooling down phase had
not been reached.
The interior drum
lighting does not come
on.
The lighting switches off
automatically (to save
energy).
Switch the dryer off
and then on again.
If the lamp needs to be
replaced, follow the
instructions in
"Changing the lamp".
Problem solving guide
38