Gas connection

Gas supply

Installation material (hoses and adapters) must be provided by the installer.

Gas connection distances

This appliance must be installed with its own shut off valve on the gas supply line. The valve must be within 6 ft.

(1.8 m), and in the same room, of the dryer.

An 1/8" NPT pressure tapping plug must be installed immediately upstream of the gas supply connection. This allows the gas inlet pressure to be checked.

￿Flare union adapter

￿1/8" NPT pressure tapping plug

￿Gas shut-off valve

For convenience (if allowed by code), an AGA or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas shut-off valve and the dryer. This will allow the appliance to be moved from the installation site for cleaning or servicing. Make sure that nothing rubs on the gas hose.

If there is any doubt concerning installation, contact the Miele Technical Service Department at the phone number listed on the back of this manual.