Installation site
Confined space installation
When installed in any space with less than 122 square feet, minimum clearances around the dryer must be adhered to for proper ventilation and vents for make up air must be installed.
Do not install any other
Confined door openings
Any doors limiting circulation must be louvered or otherwise ventilated.
A minimum of 200 square inches (1,290 cm2) of opening is required. It must be equally divided within 12" (30.5 cm) from the top and bottom of the door.
Minimum installation clearance
Sides: 0 " (0 cm) |
Top: 12" (30.5 cm)
Rear: 0" (0 cm) (as close to wall as gas connection and venting allows)
Front to door: 2" (5 cm)
Make sure the dryer door can open completely once installed.
Exhaust duct clearance
to combustible material: 2" (5 cm)