Receptacle Wiring

Receptacle wiring must be of adequate size for unit. Refer to unit identification plate for exact power requirements. Power requirements can also be determined by the type of plug on unit. See Table 1 on preceding page. Minimum size of wiring, based on

power

requirements,

is:

Units

up to 20 amps:

12 gauge

20-30

amp units:

10 gauge

Use copper wire only. It is owner'sresponsibilityto provide proper and adequate receptacle wiring that conforms to all applicable codes. All wiring should be installed by a qualified electrician.

Window Installationn7000 and 9000 Btu

Units (Models 78079, 70089)

ICAUTIONI

To avoid risk of personal injury, property damage, or product damage due to weight of device and sharp edges that may be exposed:

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install unit. To prevent injury or strain, use proper lifting and carrying methods.

Carefully inspect location where air conditioner will be installed. Be sure it will support weight of unit for extended period of time,

Handle air conditioner with care. Wear protective gloves whenever lifting or carrying unit. AVOID sharp metal fins on front and rear coils.

Make sure air conditioner does not fall dudng installation.

Required Tools and Equipment

Tight-fitting gloves

Standard screwddver

Phillips screwdriver

Pliers

Sharp knife

Carpenters'level

3/8"open-end wrench or adjustable wrench

1/4"hex socket and ratchet

Tape measure

Electdc drill

1/8"drill bit

Installation Kit Parts

Window installation kit contains the following parts. Be sure all parts are included before starting installation. If parts are missing, contact Sears.

NOTE: Parts are listed in the order

used and are

 

illustrated in Figure 3.

 

 

Item #

Description

 

Quantity

 

 

A

Window sill gasket (½"

x ¼")

40"

B

1¼" adjusting foot

 

1

C

Support bracket

 

1

D

%" hex-head screw

3

E

Sash bracket

 

1

F

%" Phillips screw

 

3

G

Window seal stdp (3A"x 1½")

40"

Figure 3. Window Installation Kit Parts