Kenmore 78079, 78189, 70129, 70089 owner manual Installation, Secudng Outer Case in Wall Opening

Models: 78079 70089 78189 70129

1 28
Download 28 pages 63.92 Kb
Page 19
Image 19
Figure 34. Secudng Outer Case in Wall Opening

Installation

Figure 34. Secudng Outer Case in Wall Opening

1.Lintel and flashing (if required)

2.Provide %" slope to outside for condensate drainage

3.Attach outer case to framing in two places on each side of case

4.Completely caulk or seal all four sides of outer case

5.Outer case extends into room _"

i

%

%

5

Masonry Construction

See Figure 32 for dimensions of finished opening to cut out or build into masonry wall. Seal outer case in place with mortar or secure to wall with concrete nails driven through sides of case.

NOTE: Ifsecudng case with concrete nails, pre-drill holes in case before driving nails into wall.

Installation in Walls Exceeding

Outer Case Dimensions

Air conditioner must be installed so air flows freely through side louvers to prevent overheating of compressor and fan motor. If dimensions of wall restrict airflow to louvers, wall opening must be modified by chamfering vertical portions of outside opening, as shown in Figures 35 and 36.

Figure 35. Chamfering Walls That Exceed Outer Case

Dimensions (Top View)

1.Outer case extends into room sA"

2.Distance from front of outer case to side louvers

f2000 Btu

18000 Btu

I

9 inches

14Y2inches

I

3.Caulk around outer case to seal in place

4.Mortar

5.4" clearance required for unrestricted air flow

6.Side louvers

Figure 36. Chamfering Walls That Exceed Outer Case

Dimensions (Side View)

1.Outer case extends into room _"

2.Distance froomfront of outer case to side louvers

120009inchesBtu I 18000Btu14V2 inches 1

3.Caulk around outer case to seal in place

4.Install outer case with %" slope to outdoor side

5.install lintel and/or flashing, if necessary

!

5

_<---- 2

4

Page 19
Image 19
Kenmore 78079, 78189, 70129, 70089 owner manual Installation, Secudng Outer Case in Wall Opening