C/E-R-TX-FX-01 IN THE NETWORK
TECHNICAL SPECIFICATIONS
SWITCH
100 meters
MDI switch setting
PST (UP) switch setting
Do NOT connect media converters between hubs. Install no more than two (2) media converters in series.
2 kilometers - multimode
20 kilometers - singlemode
SWITCH
100 meters
Standards | IEEE 802.3 |
|
Case Dimensions | 5.7" x 3.0" x 1.8" | (145mm x 76mm x 46mm) |
Shipping Weight | 3 pounds | (1.4 kilograms) |
Delay | 400nsec round trip |
|
Environment | Temperature: | |
| Humidity | |
| Altitude |
Power Supply Requirements Replace power supply with only the equivalent input rating (see below) and output rating (unregulated
TN PN | Requirement | Location |
3507 | 240 volts, 50 hertz | United Kingdom |
3342 | 230 volts, 50 hertz | Europe |
3340 | 120 volts, 60 hertz | USA/Canada/Mexico |
3346 | 100 volts, | Japan |
3511 | 240 volts, 50 hertz | Australia |
3537 | (with power cord: 3522) | South Africa |
Warranty | Lifetime |
|
NOTE: Media Converter
MDI switch setting
PST (DOWN) switch setting
Recessed switches located on each side of the media converter are used to configure the media converter for the network. NOTE: Switch labels are located
AT TOP of
(One for each
attached station to transmit and receive sequentially.
Port Select Timer (UP) Selects timer duration of eleven (11) seconds. (DOWN) Selects timer duration of five (5) seconds.
|
|
| DECLARATION OF CONFORMITY |
|
|
| |
|
|
| |
|
|
| |
|
|
|
|
| Name of Mfg: | Transition Networks | |
|
| 6475 City West Parkway, Minneapolis MN 55344 USA | |
| Model: | Redundant Fast Ethernet™ Media Converters | |
| Part Number: |
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
|
|
| _May 1, 1999_____ |
| Stephen Anderson, | Date | |
|
|
|
|