CABLE SPECIFICATIONS

CABLE SPECIFICATIONS

The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications.

Fiber Cable

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

 

85 / 125 µm multimode fiber

 

50 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Wavelength :

850nM

 

Bit error rate:

10-9

 

Maximum Cable Distance:

2 kilometers

 

SINGLEMODE

 

 

Fiber Optic Cable Recommended:

9 µm singlemode fiber

Wavelength:

1300nM

 

Bit error rate:

10-9

 

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 dBm

max: -8.0 dBm

Maximum Cable Distance:

20 kilometers

 

Copper Cable

Category 5 twisted-pair copper wire is required. Either shielded twisted- pair (STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation

20 dB/1000’ @ 10 MHz

Differential Characteristic Impedance

100 Ω ±10% @ 10 MHz

Maximum Cable Distance:

100 meters

INSTALLATION

Set Switches

Use small flatblade screwdriver or similar device to set recessed switches according to site installation.

Set EACH MDI/MDI-X switch to MDI for cable connection between switch and media converter OR to MDI-X for cable connection between media converter and terminal, transceiver or network interface card (NIC).

Referring to drawing on page 2, set four-position switch according to network configuration.

NOTE: If connecting two (2) media converters in series, set the PST (#4) switch on one media converter to the UP position AND set the PST (#4) switch on the other media converter to the DOWN position.

Install Slide-In-Module in E-MCC-1600 Chassis

Remove Media Converter Slide-in-Module protective plate from selected installation slot by removing two (2) screw that secures plate to front of E-MCC-1600.

Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media Converter Slide-in-Module with installation guides. NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated against backplane.

Secure Slide-in-Module by installing panel fastener screw attached to Slide-in-Module.

Install Cable

COPPER

NOTE: KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE.

• Locate or build 802.3 compliant cables with straight through

 

configuration and male RJ-45 plug connectors.

Connect male RJ-45 plug connector at one end of cable to media

 

converter RJ-45 jack connector.

Connect male RJ-45 plug connector at other end of cable to DTE

Twisted Pair #1

Twisted Pair #2

Straight Through Cable

11

22

33

66

The two active pairs in a 100BASE-TX network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.

terminal RJ-45 jack connector (with MDI switch set to MDI-X) or to

switch RJ-45 jack connector (with MDI switch set to MDI).

FIBER

Locate or build 802.3 compliant fiber cable with male two-stranded TX to RX connectors appropriate to the media converter installed at both ends.

Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on media converter.

Connect male TX and RX cable connectors at other end of cable to RX and TX connectors of 802.3 compliant fiber device.