SECTION 4 − INSTALLATION

4-1. Specifications

Primary

 

Primary

Primary Service

Secondary

Secondary

 

 

Rated

Power

Max**

 

 

 

Cutting

OCV

Volts

 

Amperes

(Recommended)

Volts (DC)

Amperes

KW

KVA

Capacity

Factor

(DC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.25 in

 

 

120

 

20.32

20A

110

12

2.01

2.44

(6.4 mm)

0.82

335

 

(0.25*)

At 6 IPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2.5 mm/s)

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

 

**10% High line condition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-2. Specifications For Torch

Air-cooled torch for plasma arc cutting (PAC)

35% duty cycle

Compressor output: 1.2 scfm (28.3 L/min) at 50 PSI (345 kPa) at 700 ft (213 m)

Safety interlock devices shut down power source

Safety trigger guard

Cutting capacity: see Section 4-1

4-3. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min- utes that unit can cut at rated load without overheating.

 

 

If unit overheats, thermostat(s)

 

 

opens, output stops, Temperature

 

 

trouble light goes On, and cooling

 

 

fan runs. Wait fifteen minutes for

 

 

unit to cool or temperature light to

3-1/2 Minutes Cutting

6-1/2 Minutes Resting

go off. Reduce amperage or duty

cycle before cutting or gouging.

 

 

Y Exceeding duty cycle can

 

damage unit and void

Overheating

warranty.

 

0

15

Minutes

duty1 4/95 − 802 459-B

OM-2248 Page 10

Page 14
Image 14
Miller Electric 125C, ICE-12C manual Installation, Specifications For Torch, Duty Cycle And Overheating