Image 25

6-2. Optional Auxiliary Power Receptacles

Simultaneous Welding And Auxiliary Power

Output

Weld Current

 

120 V

240 V

 

Watts

Receptacle

Receptacle

 

Amperes

 

 

Amperes

Amperes

 

 

 

 

 

 

 

 

 

250

3500

31

15.5

 

225

4260

39

19

 

200

5140

46

23

 

150

6700

60

30

 

100

8000

62.4

31.2

 

50

8000

62.4

31.2

 

0

8000

62.4

31.2

 

 

 

 

 

 

YIf unit does not have GFCI re-

ceptacles, use GFCI- protected extension cord.

.Auxiliary power decreases as weld current increases.

Combined output of all receptacles

1limited to 8 kVA/kW rating of the generator.

GFCI Receptacle Option

1120 V 15 A AC GFCI Recep- tacles GFCI2 and GFCI3

GFCI2 and GFCI3 supply 60 Hz single-phase power at weld/power speed. Maximum output from GFCI2 or GFCI3 is 2.4 kVA/kW. Cir- cuit breaker protection is the same as standard receptacles.

If a ground fault is detected, the GFCI Reset button pops out and the circuit opens to disconnect the faulty equipment. Check for damaged tools, cords, plugs, etc. connected to the receptacle. Press button to reset receptacle and resume operation.

.At least once a month, run engine at weld/power speed and press Test button to verify GFCI is working properly.

Ref. ST-189 925-A