SECTION 3 − INTRODUCTION

3-1. Included with Your Unit

1

1 Power Source

2 Power Cord (4m)

3 Work Cable and Clamp (4m)

2

4 Running Gear

3

4

3-2. Specifications

 

Rated Output

Welding

 

 

 

 

 

 

at 45% Duty

 

 

 

 

 

 

Cycle

Range

Max. OVC

Input Rating

KVA

Dimensions

Net Weight

 

 

 

 

 

 

 

 

Blu-Fab 3500

350 A 32 V

16-32

38

400−18A

11.8 KVA

Length: 1040mm

146 kg

 

 

 

 

 

 

Height: 760mm

 

 

 

 

 

 

 

Width: 435mm

 

 

 

 

 

 

 

 

 

Blu-Fab 4500

450 A 37 V

14-37

47

400-27A

17.7 KVA

Length: 1040mm

156 kg

 

 

 

 

 

 

Height: 760mm

 

 

 

 

 

 

 

Width: 435mm

 

 

 

 

 

 

 

 

 

3-3. Duty Cycle Chart

Duty cycle is percentage of 10 minutes that unit can weld at rated load without overheating.

YExceeding duty cycle can damage unit and void warranty.

WELDING AMPERES

800

 

 

 

700

 

Blu-Fab 3500: 45% Duty Cycle at 32V, 350A

600

 

 

Blu-Fab 4500: 45% Duty Cycle at 37V, 450A

500

 

 

 

 

400

 

 

 

300

450

 

 

 

350

4.5 Minutes

5.5 Minutes

200

Welding

Resting

 

2025 30 35 40 50 60 708090100

%DUTY CYCLE

3-4.

Volt-Ampere Curves

 

 

Blu-Fab 3500

Blu-Fab 4500

 

 