8 Printed Circuit Board PC3
9 Three-Way Connector
Connect three-way connector to matching receptacle on PC3, torch connection receptacle, and remote trigger receptacle.
Reinstall top of case.
Keep away from moving parts.
swarn8.1* 10/91
Turn Off cutter and remove input power. Remove top of cutter case.
1 Remote Trigger Leads
2 Strain Relief
3 Boot
Install strain relief in location shown. Insert leads through boot and install in strain relief as shown. Be sure insulation jacket is in strain relief.
4 Torch Connection Receptacle
5 Gas Hose
6 Pilot Lead
Insert receptacle, hose, and lead through boot.
7 Pilot Terminal
3-2. Installing Machine-Held Torch And Remote Trigger Pendant
WARNING |
ELECTRIC SHOCK can kill. | HOT PARTS can cause severe burns. |
• Do not touch live electrical parts. | • Allow cooling period before maintaining or servicing. |
•Turn Off cutter, and disconnect input power before installing torch.
MOVING PARTS can cause injury.
•
Significant DC voltage can remain on capacitors in cutter after unit is Off. Always discharge capacitors according to cutter’s Owner’s Manual before installing torch.
9
4
5
6
1
|
| Connect pilot lead to terminal, and |
Rear Panel | 3 | gas hose to fitting as shown. |
85
9
4 3
7 | 2 | 6 |
| 1 | |
|
|
Tools Needed:
3/8, 5/8 in