SECTION 4 − INSTALLATION

4-1. Specifications

 

Rated

Amperage/

 

Amperes Input at Rated Load Output 50/60 Hz,

 

 

 

 

 

 

Three-Phase

 

 

 

 

Model

Welding

Max OCV−DC

 

 

 

 

 

 

Voltage Range

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

230 V

380 V

400 V

440 V

460 V

575 V

KVA

KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

78 VDC In

 

 

 

 

 

 

 

 

 

 

5 − 500A In CC

CC Mode For

 

 

 

 

 

 

 

 

 

 

60 Hz

 

 

 

 

 

 

 

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

80 VDC In CC

 

 

 

 

 

 

 

 

 

450 A @ 38

 

 

 

 

 

 

 

 

 

 

 

Mode For 50 Hz

57

34

33

30

29

23

22.6

21.0

450 Amp

Volts DC, 100%

 

 

 

 

 

 

 

 

 

 

 

78 VDC In

*2.18

*1.11

*1.05

*.950

*1.04

*0.84

*0.87

*0.29

 

Duty Cycle

 

 

 

10 − 38V In CV

CV Mode For

 

 

 

 

 

 

 

 

 

 

60 Hz

 

 

 

 

 

 

 

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

80 VDC In CV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode For 50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating.

If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding.

NOTICE − Exceeding duty cycle can damage unit and void warranty.

100% Duty Cycle

Continuous Welding

Overheating

A/V

0

 

15

 

OR

Minutes

Reduce Duty Cycle

 

duty1 4/95 / 210 976-B

OM-2252 Page 13

Page 17
Image 17
Miller Electric NT 450, NT 500 manual Installation, Specifications, Duty Cycle And Overheating