Miller Electric NT 450, NT 500 manual Troubleshooting, Trouble Remedy

Models: NT 450, NT 500

1 44
Download 44 pages 13.98 Kb
Page 30
Image 30

6-4. Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

Remedy

 

 

No weld output; unit completely inop-

Place line disconnect device in On position (see Section 4-14).

erative; pilot light PL1 off.

 

 

 

 

 

 

 

 

 

Check for open line fuse(s), and replace if open (see Section 4-14).

 

 

 

 

 

 

 

Check for proper input power connections (see Section 4-14).

 

 

 

 

 

 

 

Check for proper jumper link position (see Section 4-13).

 

 

 

 

 

 

 

Check fuse F1, and replace if necessary (see Section 6-2).

 

 

Meter displays a HELP message.

If meters display a HELP message, see Section 6-3.

 

 

No weld output; pilot light PL1 on.

Check for open line fuse(s), and replace if open (see Section 4-14).

 

 

 

 

 

 

 

Check for proper input power connections (see Section 4-14).

 

 

 

 

 

 

 

Check for proper jumper link position (see Section 4-13).

 

 

 

 

 

 

 

Unit overheated. Allow unit to cool with fan On (see Section 4-2).

 

 

 

 

 

 

 

If using remote control, place Panel/Remote control switch in Remote position, and connect remote

 

 

 

control (see Sections 4-11and 5-1). If remote is not being used, place switch in Panel position (see

 

 

 

Section 5-1).

 

 

 

 

 

 

 

Check, repair, or replace remote control.

 

 

Limited weld output and low

Check position of Panel/Remote control switch (see Section 5-1).

open-circuit voltage.

 

 

Check for open line fuse(s), and replace if open (see Section 4-14).

 

 

 

 

 

 

 

 

 

 

Check for proper input power connections (see Section 4-14).

 

 

 

 

 

 

 

Check for proper jumper link position (see Section 4-13).

 

 

 

 

 

 

 

Clean and tighten all weld output connections.

 

 

Unit provides only maximum or mini-

Check position of Panel/Remote control switch (see Section 5-1).

mum weld output.

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check control board PC1, front panel display board PC2, and

 

 

 

hall device HD1.

 

 

Erratic or improper weld output.

Use proper size and type of weld cable (see Section 4-8).

 

 

 

 

 

 

 

Clean and tighten all weld connections.

 

 

 

 

 

 

 

Check wire feeder installation according to Owner’s Manual.

 

 

 

 

 

 

 

Check position of Mode switch (see Section 5-1).

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check control board PC1, front panel display board PC2, and

 

 

 

hall device HD1.

 

 

No 115 volts AC output at duplex re-

Reset circuit breaker CB1 (see Section 4-7).

ceptacle or Remote 14 receptacle.

 

 

 

 

No 24 volts AC output at Remote 14

Reset circuit breaker CB2 (see Section 4-7).

receptacle.

 

 

 

 

Fan not operating. Note: fan only runs

Check for and remove anything blocking fan movement.

when cooling is necessary.

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check fan motor.

 

 

Wandering arc; poor control of arc di-

Reduce gas flow rate.

rection.

 

 

 

 

 

 

 

 

 

Select proper size tungsten.

 

 

 

 

 

 

 

Properly prepare tungsten.

 

 

Tungsten electrode oxidizing and not

Shield weld zone from drafts.

remaining bright after conclusion of

 

 

weld.

 

 

 

 

 

 

 

 

 

Increase postflow time.

 

 

 

 

 

 

 

Check and tighten all gas fittings.

 

 

 

 

 

 

 

Properly prepare tungsten.

 

 

 

 

 

 

 

Check for water in torch, and repair torch if necessary. See torch Owner’s Manual.

 

 

Digital meter not working properly.

Have Factory Authorized Service Agent check front panel display board PC2 and connections, and re-

 

 

 

place if necessary.

 

 

 

 

 

OM-2252 Page 26

Page 30
Image 30
Miller Electric NT 450, NT 500 manual Troubleshooting, Trouble Remedy