4-10. Remote 14 Receptacle Information

 

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

 

B

Contact closure to A completes 24 volts ac contactor control circuit.

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

 

J

Contact closure to I completes 115 volts ac contactor control circuit.

 

C

Output to remote control; +10 volts dc in MIG mode.

REMOTE

D

Remote control circuit common.

OUTPUT

 

 

CONTROL

E

0 to +10 volts dc input command signal from remote control.

 

 

M

Remote mode select

A/V

F

Current feedback; +1 volt dc per 100 amperes.

AMPERAGE

 

 

VOLTAGE

H

Voltage feedback; +1 volt dc per 10 arc volts.

 

 

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

 

*The remaining sockets are not used.

 

 

4-11. Connecting Remote Control

 

 

 

! Turn off power before con-

 

 

necting to Remote 14 recep-

 

 

tacle.

 

 

1 Remote 14 Receptacle RC14

 

 

Connect remote control to RC14.

B A K J I

1

C L N H

D M G

E F

OROR

Ref. 800 166-D / Ref. S-0004-A / S-0750

OM-2243 Page 18