5-2. Controls For CE Models

3

2

1

 

 

4

Front Panel

5

LO

6 CC

7

HI

CV

Internal Control Panel

Internal Side View

1Power Control Switch

2Trigger Hold Switch

Depress the upper part of the switch (turns trigger hold On) to weld without holding gun trigger throughout the weld cycle.

To start weld, press and release gun trigger. To end weld, press and release gun trigger.

Depress the lower part of the trigger hold switch to turn trigger hold Off.

3 Purge Switch

Press switch to momentarily ener- gize gas solenoid and purge air from gun, and to adjust shielding gas regulator.

4 Wire Speed Control

Use control to adjust wire speed within range selected by switch.

5 Jog Switch

Use Jog position to momentarily feed welding wire at speed set on Wire Speed control without ener- gizing welding circuit or shielding gas valve.

6 HI/LO Range Switch

Use switch to select high or low wire speed range. High range is 100 to 700 ipm. Low range is 50 to 350 ipm.

7 CC/CV Switch

Use switch to match wire feeder with welding power source output.

Close and latch door.

Ref. 803 626-A / Ref. 802 706-A / Ref. 203 745 / Ref. 203 749