, | Cancels three wire disable. |
display returns to |
Testing Sprinkler Manual Operation
See FIGURE 2 during these procedures.
WAITING FOR LOAD
******************
Test sprinkler by manually running any drycode that calls for heat, then pulling the manual trip handle. Before beginning, turn OFF water valve. This prevents water from flooding the machine during this test.
After the power up sequences, the display shows
WAITING FOR LOAD
******************
Accesses Manual Load menu.
SELECT DRYCODE 00 REDRY
For Quick Return to Run Mode from SPRINKLER TEST
, | , | returns to automatic |
etc., |
WAITING FOR LOAD
******************
Accepts the default Drycode 00 and prompts for load size (if machine configured for more than one cake).
Accepts the default load size (full load) and prompts the operator to load dryer. Ignore this prompt.
Starts the cycle. When loading sequence ends, display appears as shown below.
ENTER LOAD SIZE 0 FULL LOAD
LOAD DRYER WITH REDRY
LOADING
00F TIF TOF 000 VP
XX XXXAXXX XXX XXX
alternates
with
00F TIF TOF 000 AIR XXX XXXDXXX XXX XXX
6