PRODUCT FEATURES AND CONTROLS

PRODUCT FEATURES AND CONTROLS

ASH DRAWER

The large ash drawer located on the left side of the ped- estal is designed to make cleaning easier by containing the ashes in a removable drawer.

CAUTION: DO NOT OPERATE THE STOVE WITH THE ASH DRAWER OPEN OR AJAR, AS THIS WILL PRODUCE EXTREME TEMPERATURES WITHIN THE STOVE (OVERFIRING) AND COULD CAUSE DAMAGE (SUCH DAMAGE IS NOT COVERED BY THE MANU- FACTURERS' WARRANTY). REPLACE THE ASH DRAWER GASKET IF IT BECOMES FRAYED OR DAMAGED.

PRIMARY AIR CONTROL

The primary combustion air delivery is controlled by the Primary Air Control Assembly (The control handle is lo- cated below the fuel door). The heat output can be con- trolled by sliding the handle to a higher or lower heat out- put setting (See Care and Operation Section – Primary Air Control, page 14). The fuel, the amount of heat and burn times desired, the type of installation are all vari- ables that will affect the control setting. The same control settings in a variety of installations will produce different results. You will need to try different settings so you can learn how much heat to expect and how long the fire will burn. The same control settings in a variety of installa- tions will produce different results. You will need to try different settings so you can learn how much heat to ex- pect and how long the fire will burn.

CARE AND OPERATI0N

FUEL DOOR

CAUTION: WHEN OPENING THE DOOR, DO NOT EX- TEND IT BEYOND ITS NORMAL TRAVEL. OVEREX- TENDING THE DOOR TO A FURTHER OPEN POSITION CAN PUT EXCESSIVE STRESS ON HINGE AREA OF DOOR AND HINGE PINS AND MAY RESULT IN BREAK- AGE.

DOOR OPERATION

The door handle assembly opens and securely latches the fuel door closed (see illustration above). To open the door, rotate the coil handle to the 9:00 position until door releases. To close and latch, hold the coil handle in the 9:00 position, close the door, then rotate the handle to the 6:00 position. See illustration above.

GLASS

The Glass is a super heat resistant ceramic that with- stands continuous temperatures up to 1390°F. This tem- perature is well beyond the temperatures in which you operate your stove. If the glass ever becomes damaged in any way, replace it, using only 5mm ceramic glass (catalog # G2000-7).

This appliance is designed to provide a flow of air over the inside of the glass, which along with high heat helps keep it clean. When operating the stove on low for ex- tended periods of time, the glass may get dirty. A short, hot fire (15 - 20 minutes) will help clean off much of the normal buildup (see troubleshooting). A commercial glass cleaner designed for stoves is recommended for cleaning.

The glass should be cleaned thoroughly with glass cleaner and a soft cloth BEFORE the stove is burned.