PLANNING YOUR INSTALLATION
COMBUSTIBLE WALL CLEARANCE
WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES.
There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney. Minimums are first estab- lished for the stove itself and increased based on how much heat is transferred by each class of pipe.
Note: Manufactured (mobile) home installations require the use of a Type L Vent Chimney connector only. Use of a single wall flue pipe connection is not permitted.
Residential Reduced Clearance
Using Listed L Vent pipe (double wall air insulated) to the top of the stove.
Approved brands are:
Clearances (inches / millimeters) |
| |||||
A. | 10 | ½ / 267 | C. | 15 | / 381 | E. 9 ½ / 241 |
B. | 20 | / 508 | D. | 8 / | 203 | F. 5 / 127 |
Residential Standard (not approved for manufac- tured [mobile] homes)
Using single wall pipe connector to the top of the stove.
Clearances (inches / millimeters) |
| |||
A. | 15 / 381 | C. | 15 / 381 | E. 8 ½ / 216 |
B. | 19 / 483 | D. | 13 / 330 | F. 5 / 127 |
Manufactured (Mobile) Home Standard Clearance
Using Approved L Vent only. Approved brands are
Clearances (inches / millimeters) |
|
| |||
A. 10 | ½ / 267 | C. 15 | / 381 | E. 9 | ½ / 241 |
B. 20 | / 508 | D. 8 / | 203 | F. 5 | / 127 |
CORNER
INSTALLATION
PARALLEL
INSTALLATION
*ALCOVE CLEARANCE
Required pipe: Type
Alcoves must have minimum dimensions of 84" (213 cm) height minimum, 46" (117 cm) width minimum and 24" (610 mm) depth maximum.
Alcove Clearances: |
|
Back wall to pipe O.D. | 10 1/2" (267 mm) Minimum |
Side wall to pipe O.D. | 20" (508 mm) Minimum |
Back wall to stove | 8" (203 mm) Minimum |
Side wall to stove | 9 1/2" (241 mm) Minimum |
*NOTE: Alcove dimensions cannot be reduced by the use of
PROTECTED WALL CLEARANCE when the stove is in- stalled adjacent to a protected wall system. The variance must be approved by your local building official. Normally, the pro- tected wall system is defined as a non- combustible material with a minimum of 1" air space behind. Check your local build- ing codes or with a qualified installer (Ref. NFPA 211).
OPTIONAL ARCH TREATMENT
An alcove depth of 24" (610 mm) (or less) will allow for a minimum height of 84" (213 cm) and may be trimmed with a 2 1/4" (57 mm) maximum arch treatment if desired.