FUNCTIONAL DESCRIPTION
GROUNDING
|
| 7 |
|
| Cat. No. 5211 |
|
| 3" |
1 |
| 6 |
|
| |
2 |
|
|
| 3 |
|
|
| 5 |
| 7 | 4 |
|
| |
|
| 6 |
|
| Cat. No. 5223 |
1 |
| 5" |
2 |
|
|
3 |
|
|
4 |
| 8 |
|
| 7 |
|
| 6 |
1 |
| Cat. No. 5243 |
1. Trigger |
| 6" |
2.Motor housing
3.Spindle housing 2 (insulated handle)
WARNING
Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electri- cian if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the cord or plug is damaged. If damaged, have it repaired by a MILWAUKEE service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.
Grounded Tools:
Tools with Three Prong Plugs
Tools marked “Grounding Required” have a three wire cord and three prong grounding plug. The plug must be connected to a prop- erly grounded outlet (See Figure A). If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock.
The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire con- nected to the tool's grounding system and must never be attached to an electrically “live” terminal.
Your tool must be plugged into an appropri- ate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in Figure A.
Double Insulated Tools:
Tools with Two Prong Plugs
Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association and the National Electrical Code. Double Insulated tools may be used in either of the 120 volt outlets shown in Figures B and C.
4. | Guard assembly clamp | 3 |
|
5. | Faceplate | 4 | 5 |
|
|
6.Guard assembly
7.Tool rest
8.Spindle Nut
Specifications
Cat. | Volts | Grounding Req. or | No Load | Arbor Size | Wheel Size |
Diameter, | Thickness, | ||||
No. | AC/DC | Double Insulated | RPM | Threads | Diameter |
5211 | 120 | Double Insulated | 14500 | 3/8" - 24 | 1/2" x 3" |
5223 | 120 | Double Insulated | 7000 | 5/8" - 11 | 1" x 5" |
5243 | 120 | Grounding Required | 5700 | 5/8" - 11 | 1" x 6" |
|
|
|
|
|
|
Fig. A | Fig. B | Fig. C |
|
Symbology
| Double Insulated |
| Volts Alternating Current/ |
|
| Direct Current | |
|
|
| |
|
|
|
|
| Underwriters Laboratories, Inc., |
| No Load Revolutions per |
| United States and Canada |
| Minute (RPM) |
|
|
|
|
| Amps |
| Mexican Safety |
|
| Standards | |
|
|
| |
|
|
|
|
6 | 7 |