- 55 -
COLOR CORRECTION
Variation Correction – Saturation:
“Adjust Correction Level”slide bar
“Display Limit”checkbox
If you selected the “Saturation”variation option, showing the “Current” image in the center, two other
simulation images are displayed in the horizontal direction, where each simulation image has been
corrected by one level (“Less”and “More”) to the “Current” image.
If you click one desired simulation image, newly simulated images are displayed by replacing the current
image with the selected simulation image.
If you drag the control of the “Adjust Correction Level”slide bar with the mouse, you can change the
degree of the correction by one level from the initial value (10) to another within the range of 1 through 20.
If you check the “Display Limit”checkbox, parts of simulation images that exceeded their display limits (0
or 255) will be reversed when you corrected “Saturation”.
You can cancel all kinds of correction performed in the “Saturation”variation by clicking “Reset”.The
current image in the center and two simulation images will return to the status when this “Variation”window
appeared for the first time.