COMMUNICATION INTERFACE

(1) RS232

 

 

 

 

 

NC-----------------

1

NC-----------------

6

 

TXD---------------

2

NC-----------------

7

 

RXD---------------

3

NC-----------------

8

 

NC-----------------

4

NC-----------------

9

 

Signal Ground---

5

 

 

Pin2:

UPS transmits serial data to computer.

 

Pin3:

UPS receives serial data from computer.

 

Pin5:

Signal ground.

 

 

 

The RS232 communication port provides the following features:

¨Monitoring charger status

¨Monitoring battery status and condition

¨Monitoring inverter status

¨Monitoring UPS status

¨Monitoring the utility status

¨Remote control shutdown of UPS

All information is provided in ASCII format.

HARDWARE:

BAUD RATE ————————— 2400 BPS DATA LENGTH ———————— 8 bits STOP BIT ——————————-1 bit PARITY ———————————-NONE

CABLING:

COMPUTER

RX (Pin2)

TX (Pin3)

GND (Pin5)

(1) DRY CONTACT

¬

®

®

UPS

TX (Pin2)

RX (Pin3)

GND (Pin5)

NC-----------------

1

Low Battery--------

6

NC-----------------

2

NC-----------------

7

Shut Down-------

3

NC-----------------

8

AC Fail------------

4

NC-----------------

9

Signal Ground---

5

 

 

Pin4: Output signal transfers from HIGH to LOW during utility failures. The pin is normally HIGH.

Pin6: Output signal transfers from HIGH to LOW upon battery low. The pin is normally HIGH.

Pin9: The UPS will shut down when HIGH remains constant for at least 3.8 seconds.

Pin5: Signal ground.