68
Parameter list
242 Terminal 1 added compensation
amount (terminal 2) 0 to 100% 0.1% 100% 175
243 Terminal 1 added compensation
amount (terminal 4) 0 to 100% 0.1% 75% 175
244 Cooling fan operation selection 0, 1 1 1 300
Slip
compensation
245 Rated slip 0 to 50%, 9999 0.01% 9999 80
246 Slip compensation time constant 0.01 to 10s 0.01s 0.5s 80
247 Constant-power range slip
compensation selection 0, 9999 1 9999 80
250 Stop selection
0 to 100s,
1000 to 1100s, 8888,
9999
0.1s 9999 119
251 Output phase loss protection
selection 0, 1 1 1 162
Frequency compensation
function
252 Override bias 0 to 200% 0.1% 50% 175
253 Override gain 0 to 200% 0.1% 15 0% 175
Life check
255 Life alarm status display (0 to 15) 1 0 301
256 Inrush current limit circuit life display (0 to 100%) 1% 100% 301
257 Control circuit capacitor life display (0 to 100%) 1% 100% 301
258 Main circuit capacitor life display (0 to 100%) 1% 100% 301
259 Main circuit capacitor life measuring 0, 1 1 0 301
260 PWM frequency automatic switchover 0, 1 1 1 169
Power failure stop
261 Power failure stop selection 0, 1, 2, 21, 22 1 0 156
262 Subtracted frequency at deceleration
start 0 to 20Hz 0.01Hz 3Hz 156
263 Subtraction starting frequency 0 t o 400Hz, 9999 0.01Hz 60Hz 156
264 Power-failure deceleration time 1 0 to 3600/ 360s 0.1/0.01s 5s 156
265 Power-failure deceleration time 2 0 to 3600/ 360s,
9999 0.1/0.01s 9999 156
266 Power failure deceleration time
switchover frequency 0 to 40 0Hz 0.01Hz 60Hz 156
267 Terminal 4 input selection 0, 1, 2 1 0 171
268 Monitor decimal digits selection 0, 1, 9999 1 9999 141
269 Parameter for manufacturer setting.
Do not set.
Password
function
296 Password lock level 0 to 6, 99, 101 to 106,
199, 9999 19999192
297 Password lock/unlock (0 to 5), 1000 to 9998,
9999 19999192
299 Rotation direction detection selection
at restarting 0, 1, 9999 1 9999 152
Function Parameters
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting