Mitsubishi Electronics MCF-18TN/24TN manual AIR Flow Velocity and Direction Adjustment

Models: MCF-18TN/24TN

1 24
Download 24 pages 42.99 Kb
Page 8
Image 8

AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT

AIR FLOW velocity and direction can be selected as required.

˚C

CLOCK

AMPM

AMPM

ON/OFF TOO TOO

WARM COOL

FAN

STOP

I FEEL COOL

 

VANE

START

FAN DRY

 

MODE

HR.

ECONO COOL

MIN.

RESET CLOCK

 

To change the AIR FLOW velocity, press the FAN button.

Each time the button is pressed, the fan speed is changed

in sequence:(Low) (Med.) (High) (AUTO)

Use the(High) notch to cool the room more.

If the operating sound of the air conditioner disturbs your sleep, use the(Low) notch.

To change the AIR FLOW blowing direction vertically, press the VANE button.

Each time the button is pressed, the angle of the hori- zontal vane is changed in sequence : 1 2 3 4

5 (SWING) (AUTO)

SWING OPERATION

Use the swing operation for the air flow to reach all cor- ners of the room.

Recommended horizontal vane range

Use the (AUTO) position usually.

Use position 1 or 2 in the COOL or DRY mode when adjusting to your requirements.

 

 

COOL

 

1

 

DRY

 

2

 

 

 

 

 

 

3

 

 

 

4

 

 

 

5

1

COOL

 

 

DRY

 

 

2

 

3

4

5

Notes:

In the cooling operation, when the air conditioner is operated with setting the horizontal vane to 4 or 5 for 1 hour, the AIR FLOW direction is automatically set to position 1 to prevent condensed water from dropping.

Adjust the vertical AIR FLOW direction using the re- mote controller. If the horizontal vane is moved manu-

ally, it may cause trouble.

To change the horizontal direction of the AIR FLOW

For the floor standing unit

For the ceiling suspended unit

• Change the direction of the vertical vane manually.

• Change the direction of the vertical vane manually.

Adjust the vane before operation starts.

Since the horizontal vane moves automatically, your fingers may be caught.

AUTO AIR FLOW DIRECTION CONTROL OPERATION

When the AUTO mode is selected with the VANE button, the position of the horizontal vane is automatically set to correspond to the operation mode for effective operation.

For the floor standing unit

 

 

 

 

 

 

 

 

 

 

 

 

(1) COOL, DRY

 

 

(2) FAN

 

• The air is blown out upwards.

• The air is blown out horizontally.

For the ceiling suspended unit

 

 

 

 

 

 

 

 

(1) COOL, DRY

 

 

(2) FAN

 

• The air is blown out horizontally.

• The air is blown out downwards.

8

Page 8
Image 8
Mitsubishi Electronics MCF-18TN/24TN AIR Flow Velocity and Direction Adjustment, Auto AIR Flow Direction Control Operation