U-11

Remote control (continued)

Carry out as necessary

 

 

 

 

 

2)Control command diagram

The command is structured by the address code, function code, data code and end code. The length of the command is different for each function.

NOTE:

This example shows a basic command that is used when a single computer and a single monitor are connected.

When you want to connect multiple monitors or perform complicated control using other commands than the basic commands, contact your dealer for advanced command specifications.

 

Address code

Function code

 

Data code

End code

 

 

 

 

 

 

 

 

 

HEX

 

30h 30h

Function

 

Data

0Dh

 

 

 

 

 

 

 

 

 

ASCII

 

‘0’ ‘0’

Function

 

Data

 

 

 

 

 

 

 

 

 

[Address code]

30h 30h (ASCII code, ‘0’ ‘0’), fixed.

 

 

[Function code]

Code unique to each control function.

 

 

[Data code]

 

Data unique to each control function (Not always indicated by numerical values.)

[End code]

 

0Dh (In ASCII code, ‘ ’) fixed.

 

 

 

3)Control sequence

(1)A command is sent from the computer to the monitor. (Commands should be sent at intervals of at least 600 ms.)

(2)The monitor sends a return command within 600 ms* after receiving and encoding the command. If the monitor fails to receive the command, it doesn’t send any return command.

(3)The computer checks the return command to see that the command it sent was executed or not.

(4)The monitor sends various codes other than the return code. While RS-232C control sequence is in progress, reject other

codes on the personal computer side.

*: Transmission of the return command may be delayed during signal switchover, etc. Example: Turn the power ON (‘ ’ is for ASCII code)

Command from computer

Command from monitor

Detail of command

30 30 21 0D

 

Command for POWER ON

‘0’ ‘0’ ‘!’ ‘ ’

 

 

 

 

30 30 21 0D

Command received

 

‘0’ ‘0’ ‘!’ ‘ ’

(Command echoed back)

For RS-485, both of DTR and RTS lines remain Active Low while the TXD command is sent from the computer.

4)Operation commands

The operation commands configure the basic operation settings of this LCD monitor. The commands may not work during signal switchover.

The operation commands have no data codes.

Operation

ASCII

 

HEX

 

 

 

 

 

POWER ON

!

21h

 

 

 

 

 

 

 

POWER OFF

"

22h

 

 

 

 

 

 

INPUT RGB 1

_r1

5Fh 72h

31h

 

 

 

INPUT RGB 2

_r2

5Fh 72h 32h

 

 

 

 

INPUT RGB 3

_r3

5Fh 72h

33h

 

 

 

 

INPUT RGB 4

_r4

5Fh 72h

34h

 

 

 

 

INPUT RGB 5

_r5

5Fh 72h

35h

 

 

 

 

INPUT RGB 6

_r6

5Fh 72h

36h

 

 

 

 

INPUT VIDEO

_v1

5Fh 76h

31h

 

 

 

 

INPUT DVD/HD

_v2

5Fh 76h

32h

 

 

 

 

INPUT S-VIDEO

_v3

5Fh 76h

33h

 

 

 

 

 

VOLUME UP

r06

72h

30h

36h

 

 

 

 

 

VOLUME DOWN

r07

72h

30h

37h

 

 

 

 

MUTE

ra6

72h

61h 36h

 

 

 

 

 

AUTO SETUP

r09

72h

30h

39h

 

 

 

 

 

POWER OFF command should be operated over 1 minute after the power is turned on.

POWER ON command should be operated over 1 minute after the power is turned off.

After sending any of the video input selection commands, wait for at least 10 seconds to send the next command.