Mitsubishi Electronics Wiring Diagram, MSH-A18ND Indoor Unit, MSH-A24ND Indoor Unit

Models: MSH-A18ND

1 28
Download 28 pages 27.71 Kb
Page 6
Image 6

5

WIRING DIAGRAM

MSH-A18ND

INDOOR UNIT

TO OUTDOOR

 

 

UNIT

 

 

CONNECTING

3 TB

 

12V

RED

 

N

BLU

220V~

2

BRN

HIC1

CN201

3

2

1

TAB12F11

 

CN

RT12

 

112

 

 

CN

RT11

 

111

 

 

CN 3

BLK

NR11

GRY

121YLW

C11

1

BRN MF

WHT

SR141

3

RED

 

4

 

 

 

CN211

 

 

CN

GRN/YLW

151

15

 

MV2 MV2 MV1

CN

CN

ELECTRONIC CONTROL P.C. BOARD

102

101

33

DISPLAY RECEIVER

P.C.BOARD P.C.BOARD

REMOTE

CONTROLLER

SYMBOL

NAME

 

SYMBOL

NAME

SYMBOL

NAME

 

 

 

 

 

 

C11

INDOOR FAN CAPACITOR

MV1

VANE MOTOR (HORIZONTAL)

RT12

INDOOR COIL THERMISTOR

 

 

 

 

 

 

 

F11

FUSE (3.15A)

 

MV2

VANE MOTOR (VERTICAL)

SR141

SOLID STATE RELAY

 

 

 

 

 

 

HIC1

DC/DC CONVERTER

NR11

VARISTOR

TB

TERMINAL BLOCK

MF

FAN MOTOR (INNER PROTECTOR)

RT11

ROOM TEMPERATURE THERMISTOR

 

 

 

 

 

 

 

 

NOTES: 1.About the outdoor side electric wiring, refer to the outdoor unit electric wiring diagram for servicing.

 

2.Use copper conductors only. (For field wiring)

 

 

 

3.Symbols below indicate.

 

 

 

 

 

 

: Terminal block

: Connector

 

 

 

 

MSH-A24ND

INDOOR UNIT

TO OUTDOOR

UNIT

CONNECTING

TB

12V 3

N

220V~ 2

RED

BLU

BRN

 

CN

GRN/YLW

151

15

 

MV2 MV2 MV1

 

 

 

 

4

RT13

 

 

 

 

3

 

 

 

 

 

 

 

HIC1

 

2

RT12

 

 

 

 

1

 

 

 

 

 

CN201

 

 

CN112

BLK

3

 

 

NR11

CN 3

GRY

2

 

 

 

121

YLW

1

 

 

C11

1

BRN MF

 

 

F11

WHT

TAB12

 

SR141

3

 

RED

 

 

 

 

4

 

CN

CN

 

CN211

 

ELECTRONIC CONTROL P.C. BOARD

111CN

RT11

102

101

33

DISPLAY RECEIVER

P.C.BOARD P.C.BOARD

REMOTE

CONTROLLER

SYMBOL

NAME

SYMBOL

NAME

SYMBOL

NAME

C11

INDOOR FAN CAPACITOR

MV2

VANE MOTOR (VERTICAL)

SR141

SOLID STATE RELAY

F11

FUSE (3.15A)

 

NR11

VARISTOR

TB

TERMINAL BLOCK

HIC1

DC/DC CONVERTER

RT11

ROOM TEMPERATURE THERMISTOR

 

 

MF

INDOOR FAN MOTOR (INNER PROTECTOR)

RT12

INDOOR COIL THERMISTOR (MAIN)

 

 

 

 

 

 

 

 

MV1

VANE MOTOR (HORIZONTAL)

RT13

INDOOR COIL THERMISTOR (SUB)

 

 

NOTES: 1.About the outdoor side electric wiring, refer to the outdoor unit electric wiring diagram for servicing.

 

 

2.Use copper conductors only. (For field wiring)

 

 

 

3.Symbols below indicate.

 

 

 

 

 

 

: Terminal block

: Connector

 

 

 

 

 

 

 

 

6

 

 

Page 6
Image 6
Mitsubishi Electronics service manual Wiring Diagram, MSH-A18ND Indoor Unit, MSH-A24ND Indoor Unit