AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT

Movement of the horizontal vane

AUTO

MANUAL

SWING

COOL/DRY

 

 

HEAT

 

 

 

 

At the start

 

 

 

 

 

 

of heating

 

 

 

 

 

 

operation

 

 

 

 

 

 

 

 

When air

 

 

 

 

Horizontal

Very small

becomes

 

 

 

 

position

warm…

 

Horizontal position

air flow

 

 

 

Position (4)

 

 

 

 

 

 

• The vane automatically moves to horizontal position.

• Immediately after the air conditioner starts operat-

It will not swing.

 

 

ing, the vane stays at horizontal position. Once the

NOTE:

 

 

air from the indoor unit becomes sufficiently warm,

 

 

the vane moves to position (4).

 

Air blows out upper than position (1).

 

• Once the air conditioner starts operating, the fan

• To constantly change the air flow direction, select

speed increases gradually as the air from the indoor

(SWING) with the

VANE

button.

 

unit gets warmer, and continues until the set speed

 

 

 

 

 

 

is finally reached.

 

 

 

 

 

At the start

 

 

 

 

 

 

of heating

 

 

 

After

 

operation

 

 

 

around 0.5

 

 

When air

 

to 1 hour

Position (1)

 

 

 

Horizontal

 

becomes

 

 

 

 

Very small

 

 

 

 

position

warm…

Set position

 

 

 

 

air flow

 

When the air flow direction is

 

 

 

 

 

 

 

 

 

set to position (2), (3) or (4)

 

 

 

 

 

 

• After around one hour of operation, the air condi-

• Immediately after the air conditioner starts operat-

tioner automatically moves the vane to position (1).

ing, the vane stays at horizontal position. Once the

To change the air flow direction to the original set-

air from the indoor unit becomes sufficiently warm,

ting, operate the VANE button on the remote con-

the vane moves to the position corresponding to the

troller again.

 

 

set direction of air flow.

 

• The vane does not move to the straight-down posi-

• Once the air conditioner starts operating, the fan

tion in the COOL and DRY mode.

speed increases gradually as the air from the indoor

 

 

 

unit gets warmer, and continues until the set speed

 

 

 

is finally reached.

 

 

• The vane moves intermittently between positions (1)

• The vane moves intermittently between positions (2)

and (4). The vane stops for a brief period at posi-

and (4). The vane stops for a brief period at positions

tions (1) and (4).

 

 

(2) and (4).

 

 

 

(1)

 

 

 

(2)

 

 

 

 

 

 

 

(4)

NOTE:

(4)

Adjust the vertical AIR FLOW direction using the remote controller. Moving the horizontal vane manually can cause trouble.

When the operation mode changes in “ (AUTO)” mode, the horizontal vane is automatically changed to the posi- tion in each mode.

8