Manuals
/
Brands
/
Household Appliance
/
Air Conditioner
/
Mitsubishi Electronics
/
Household Appliance
/
Air Conditioner
Mitsubishi Electronics
MSZ-GA22VA, MSZ-GA25VA, MSZ-GA35VA
- page 31
1
31
32
32
Download
32 pages, 1.43 Mb
31
OB378_--1qxp 05.1.17 12:55 Page 31
Contents
Main
SERVICE MANUAL
CONTENTS
Wireless type Models
MSZ-GA22V A - MSZ-GA25V A - MSZ-GA35V A -
No. OB378
1TECHNICAL CHANGES
MSZ-A09YV - MSZ-GA22VA - MSZ-A09YV - MSZ-GA25VA - MSZ-A12YV - MSZ-GA35VA - E1E1
PART NAMES AND FUNCTIONS
2
MSZ-GA35VA -
ACCESSORIES
SPECIFICATION
3
Specifications and rating conditions of main electric parts
4NOISE CRITERIA CURVES
MSZ-GA25VA -
1m
INDOORUNIT WALL MICROPHONE
0.8m
{
6WIRING DIAGRAM
REFRIGERANT SYSTEM DIAGRAM
7
INDOOR UNIT MODELS WIRING DIAGRAM
MF
SERVICE FUNCTIONS
8
8-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
8-1. TIMER SHORT MODE
Table 1
TROUBLESHOOTING
9
MSZ-GA22VA - MSZ-GA25VA - MSZ-GA35VA -
2 1
OB378_--1qxp 05.1.17 12:55 Page 12
9-2. Failure mode recall function
1. Flow chart of the indoor/outdoor unit failure mode recall function
Page
9-3. Instruction of troubleshooting
9-4. Troubleshooting check table
Lighted
Blinking
Not lighted
Flashing of OPERATION INDICATOR lamp (left-hand side lamp) indicates abnormalities.
MSZ-GA22VA - MSZ-GA25VA - MSZ-GA35VA -
Check of indoor fan motor
OB378_--1qxp 05.1.17 12:55 Page 17
9-6. Troubleshooting flow
A
When OPERATION INDICATOR lamp flashes 3-time. Indoor fan does not operate.
Check of remote controller and receiver P.C. board
B
OB378_--1qxp 05.1.17 12:55 Page 19
Check of indoor electronic control P.C. board and indoor fan motor
C
Indoor electronic control P.C.Board
How to check mis-wiring and serial signal error
D
When POWER lamp flashes ON and OFF in every 0.5-second. Outdoor unit does not operate.
Check of installation of the horizontal vane
OB378_--1qxp 05.1.17 12:55 Page 21
E
When All lamps flash ON and OFF every 0.5-second. Indoor unit and outdoor unit do not operate.
Electromagnetic noise enters into TV sets or radios
F
Yes
MSZ-GA22VA - MSZ-GA25VA - MSZ-GA35VA -
}
Indoor electronic control P.C. board
}
9-7. Test point diagram and voltage
Interlock switch(Fan) (CN1R1)
DISASSEMBLY INSTRUCTIONS
10
Photo 1
<"Terminal with locking mechanism" Detaching points>
MSZ-GA22VA - MSZ-GA25VA - MSZ-GA35VA -
Photo 3
3. Removing the electrical box
Photo 4
Photo 2
Photo 6
Photo 8
4. Removing the horizontal vane motor unit
Photo 5
5. Removing the indoor fan motor and the line flow fan
PARTS LIST11
MSZ-GA22VA - (WH) MSZ-GA25VA - (WH) MSZ-GA35VA - (WH) 11-1. INDOOR UNIT STRUCTURAL PARTS
11-2. ACCESSORYAND REMOTE CONTROLLER
5 6
3
11-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
MSZ-GA22VA - (WH) MSZ-GA25VA - (WH) MSZ-GA35VA - (WH)
11-4. INDOOR UNIT HEAT EXCHANGER
11-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
11-4. INDOOR UNIT HEAT EXCHANGER
12 OPTIONAL PARTS
AIR CLEANING FILTER (ANTI-ALLERGY ENZYME FILTER)