5
SPECIFICATION3
T3.15AL 250V
MSBPC20M16 12V DC 250" (at 25˚C)
ERZV14D471
3P
INDOOR UNIT
Item Model
Fuse
Horizontal vane motor
Varistor
Terminal block
MSZ-GA22VA - E1 MSZ-GA25VA - E1 MSZ-GA35VA - E1
(F11)
(MV)
(NR11)
(TB)

Specifications and rating conditions of main electric parts

MSZ-GA25VA - E1
MSZ-GA22VA - E1 MSZ-GA35VA - E1
Indoor model
Function
Power supply Single phase
230V,50Hz
10
0.25
33
57
0.25
RC0J30-CC
780O298O210
9
4
43
36W/29W/21W
4
10
10
10
KM05B
Single phase
230V,50Hz
10
0.25
33
57
0.25
RC0J30-CC
780O298O210
9
4
43
36W/29W/21W
4
10
10
10
KM05B
540
43
36W/29W/21W
1,100
43
36W/29W/22W
Cooling
600
480W/366W/234W
1,200
1,000W/800W/580W
Heating
630
504W/384W/258W
1,250
1,040W/830W/620W
Cooling
600
480W/366W/234W
1,200
1,000W/800W/580W
Heating
630
504W/384W/258W
1,250
1,040W/830W/620W
Single phase
230V,50Hz
10
0.25
33
57
0.25
RC0J30-CC
780O298O210
9
4
43
36W/29W/22W
4
10
10
10
KM05B
Cooling
600
480W/366W/246W
1,200
1,000W/800W/600W
Heating
630
504W/384W/270W
1,250
1,040W/830W/640W
Air flow(Super High)
Air flow(HighW/Med.W/LowW)
Power outlet
Running current 1
Power input 1
Auxiliary heater
Power factor 1
Fan motor current 1
Model
Dimensions WOHOD
Weight
Air direction
Sound level(Super High)
Sound level(HighW/Med.W/LowW)
Fan speed(Super High)
Fan speed(HighW/Med.W/LowW)
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Thermistor RT13(at25:)
Remote controller model
K /h
K /h
A
A
W
A(kW)
%
A
mm
kg
dB(A)
dB(A)
rpm
rpm
k"
k"
k"
Electrical
data
Fan motor
Special
remarks
Capacity
MSZ-GA25VA - E1
MSZ-GA22VA - E1 MSZ-GA35VA - E1
Indoor model
Function Cooling
438W/342W/240W
930W/760W/580W
Heating
420W/366W/258W
900W/800W/620W
Cooling
438W/342W/240W
930W/760W/580W
Heating
420W/366W/258W
900W/800W/620W
Cooling
600
480W/366W/246W
1,200
1,000W/800W/600W
Heating
618
504W/390W/270W
1,230
1,040W/850W/640W
Air flow(Super High)
Air flow(HighW/Med.W/LowW)
Sound level(Super High)
Sound level(HighW/Med.W/LowW)
Fan speed(Super High)
Fan speed(HighW/Med.W/LowW)
K /h
K /h
dB(A)
dB(A)
rpm
rpm
Special
remarks
Capacity
540
43
36W/29W/21W
1,100
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor Dry-bulb temperature 27:Wet-bulb temperature 19:
Outdoor Dry-bulb temperature 35:Wet-bulb temperature 24:
Heating : Indoor Dry-bulb temperature 20:Wet-bulb temperature 15:
Outdoor Dry-bulb temperature 7:Wet-bulb temperature 6:
Refrigerant piping length (one way): 5m
wReference value
1 Measured under rated operating frequency.
When outdoor unit is MXZ type.
OB378_--1qxp 05.1.17 12:55 Page 5