4
Outdoor unit model MUZ-GE09NA MUY-GE09NA MUZ-GE12NA MUY-GE12NA
Capacity
Rated (Minimum~Maximum)
Cooling 1 Btu/h 9,000
( 3,800 ~ 12,200 )
9,000
( 3,800 ~ 12,200 )
12,000
( 3,800 ~ 13,600 )
12,000
( 3,800 ~ 13,600 )
Heating 47 1 Btu/h 10,900
( 4,500 ~ 14,100 ) 14,400
( 5,500 ~ 18,100 )
Capacity Heating 17 2 Btu/h 8,700 11,200
Power consumption
Rated (Minimum~Maximum)
Cooling 1 W
660 (205~1,200) 660 (205~1,200) 960 (205~1,300) 960 (205~1,300)
Heating 47 1 W
760 (255~1,200)
1,170 (340~1,660)
Power consumption Heating 17 2 W 950 1,200
EER 1 [SEER] 3 Cooling 13.6 [ 21.0 ] 13.6 [ 21.0 ] 12.5 [ 20.5 ] 12.5 [ 20.5 ]
HSPF IV 4 Heating 10.0 10.0
COP Heating 1 4.20 3.61
Power supply V , phase , Hz 208/230 , 1 , 60
Max. fuse size (time delay) A 15
Min. circuit ampacity A 12 12 12 12
Fan motor F.L.A 0.50
Compressor
Model KNB073FQDHC KNB092FQAHC
R.L.A 6.6 4.9 6.6 4.9
L.R.A 8.2 6.1 8.2 6.1
Refrigeration oil cc. (Model) 320 (NEO22)
Refrigerant control Linear expansion valve
Sound level 1Cooling dB(A) 46 46 49 49
Heating dB(A) 50 51
Defrost method Reverse cycle
Dimensions
W in. 31-1/2
D in. 11-1/4
H in. 21-5/8
Weight Ib. 66 77
External nish Munsell 3Y 7.8/1.1
Remote controller Wireless type
Control voltage
(by built-in transformer)
VDC 12 - 24
Refrigerant piping Not supplied
Refrigerant pipe size
(Min. wall thickness)
Liquid in. 1/4 (0.0315)
Gas in. 3/8 (0.0315)
Connection method Indoor Flared
Outdoor Flared
Between the indoor &
outdoor units
Height difference ft. 40
Piping length ft. 65
Refrigerant charge (R410A) 1 lb. 12 oz. 2 lb. 9 oz.
NOTE: Test conditions are based on ARI 210/240.
1: Rating conditions (Cooling) — Indoor: 80˚FDB, 67˚FWB, Outdoor: 95˚FDB, (75˚FWB) Rated frequency
(Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB Rated frequency
2: (Heating) Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB Maximum frequency
3SPECIFICATION