Guidance and manufacturer's declaration - electromagnetic emissions
The Model P93DW/P93DE is intended for use in the electromagnetic environment specified below.
The customer or user of the Model P93DW/P93DE should assure that it is used in such an
environment.
Emission test
RF emissions
CISPR 11/EN 55011
RF emissions
CISPR 11/EN 55011
Harmonic emissions
IEC/EN 61000-3-2
Voltage fluctuations /
flicker emissions
IEC/EN 61000-3-3
Compliance
Group 1
Class B
Class A
Complies
Electromagnetic environment - guidance
The Model P93DW/P93DE uses RF energy only for its
internal function. Therefore, its RF emissions are very
low and are not likely to cause interference in nearby
electronic equipment.
The Model P93DW/P93DE is suitable for use in all
establishments, including domestic establishments
and those directly connected to public low-voltage
power supply network that supplies buildings used for
domestic purpose.
Guidance and manufacturer's declaration - electromagnetic immunity The Model P93DW/P93DE is intended for use in the electromagnetic environment specified below.
The customer or user of the Model P93DW/P93DE should assure that it is used in such an
environment.
Immunity test
Electrostatic
discharge (ESD)
IEC/EN 61000-4-2
Electrical fast
transient/burst
IEC/EN 61000-4-4
Surge
IEC/EN 61000-4-5
Voltage dips, short
interruptions and
voltage variations
on power supply
input lines
IEC/EN 61000-4-11
Power frequency
(50/60 Hz)
magnetic field
IEC/EN 61000-4-8
IEC/EN 60601
test level
±6 kV contact
±8 kV air
±2 kV for power
supply lines
±1 kV for input
/output lines
±1 kV
differential
mode
±2 kV common
mode
< 5%
U
T
(> 95% dip in
U
T
)
for 0,5 cycle
40%
U
T
(60% dip in
U
T
)
for 5 cycles
70%
U
T
(30% dip in
U
T
)
for 25 cycles
< 5%
U
T
(> 95% dip in
U
T
)
for 5 sec.
3 A/m
Electromagnetic environment - guidance
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should be at least 30%.
Mains power quality should be that of a
typical commercial or hospital
environment.
Mains power quality should be that of a
typical commercial or hospital
environment.
Mains power quality should be that of a
typical commercial or hospital
environment. If the user of the Model
P93DW/P93DE requires continued
operation during power mains
interruptions, it is recommended that the
Model P93DW/P93DE be powered from
an uninterruptible power supply or a
battery.
Power frequency magnetic fields should
be at levels characteristic of a typical
commercial or hospital environment.
Compliance
level
±6 kV contact
±8 kV air
±2 kV for power
supply lines
±1 kV for input
/output lines
±1 kV
differential
mode
±2 kV common
mode
< 5%
U
T
(> 95% dip in
U
T
)
for 0,5 cycle
40%
U
T
(60% dip in
U
T
)
for 5 cycles
70%
U
T
(30% dip in
U
T
)
for 25 cycles
< 5%
U
T
(> 95% dip in
U
T
)
for 5 sec.
3 A/m
NOTE
U
T
is the a.c. mains voltage prior to application of the test level.