3)Control sequence

3)Control sequence

(1)Send the command from a personal computer to the projector. (The commands must be sent at least 400ms apart.)

(2)The projector will send a return command 400ms* after it has received an end code. If the command is not received correctly, the projector will not send the return command.

(3)The personal computer checks the command and confirms if the command which has been sent has been executed or not.

(4)This projector sends various codes other than the return code. When having a control sequence by RS- 232C, reject other codes from personal computer side.

* : The sending time of return command may delay depending on the condition (during changing the input signal, etc.).

[Example] Turn the power ON (' 'is for ASCII code)

Sending commands

 

Status code from

Meaning

from the PC etc.

 

projector

 

30 30 21 0D

 

 

Command for POWER ON

'0' '0' '!' ' '

 

 

 

 

 

 

 

30 30 21 0D

Command received

 

'0'

'0' '!' ' '

(Command echo back)

4) Operation commands

The operation commands execute the basic operation setting of this projector. It may not operate when chang- ing the signal.

Operation

ASCII

HEX

 

 

POWER ON

!

21h

 

 

POWER OFF

"

22h

 

 

INPUT COMPUTER 1

_r1

5Fh

72h

31h

INPUT COMPUTER 2

_r2

5Fh

72h

32h

INPUT VIDEO 1

_v1

5Fh

76h

31h

INPUT VIDEO 2

_v2

5Fh

76h

32h

POWER OFF command will not work for 1 minute after the power is turned on.

POWER ON command will not work for 1 minute after the power is turned off.

[Example] Set the input signal to COMPUTER 1 (' 'is for ASCII code)

Sending commands

Status code from

Meaning

from the PC etc.

projector

 

30 30 5F 72 31 0D

 

Command for setting the input

'0' '0' '_' 'r' '1' ' '

 

signal to COMPUTER 1

 

 

 

 

30 30 5F 72 31 0D

Command received

 

'0' '0' '_' 'r' '1' ' '

(Command echo back)

 

 

 

5) Computer input commands (For X500U only)

The computer input commands execute INPUT SELECT setting of COMPUTER 1.

ITEM

ASCII

HEX

 

VALUE

 

INPUT SELECT

DIF

44h 49h 46h

 

0

: The same as INPUT SELECT switch setting of Terminal board.

 

 

 

 

1 : ANALOG setting (Mini D-SUB 15P).

 

 

 

 

2

: DIGITAL setting (DVI-24P).

 

 

 

 

 

 

How to set the grade

Use ASCII letters code to set the grade for setting data. Please refer to the table below for HEX code.

ASCII

'0'

'1'

'2'

HEX

30h

31h

32h

[Example] Set INPUT SELECT (of COMPUTER 1) to DIGITAL. (' 'is for ASCII code)

Sending commands

Status code from

Meaning

from the PC etc.

projector

 

30 30 44 49 46 32 0D

 

Command for setting the INPUT SELECT

'0' '0' 'D' 'I' 'F' '2' ' '

 

to DIGITAL.

 

 

 

 

30 30 44 49 46 32 0D

Command received

 

'0' '0' 'D' 'I' 'F' '2' ' '

(Command echo back)

 

 

 