Mitsubishi Electronics XD480U user manual Maintenance, Others, Cleaning of the lens

Models: XD480U

1 34
Download 34 pages 36.22 Kb
Page 29
Image 29
Others

Others

Problem

Cause and solution

 

 

Hot air is emitted from the

This air comes out as a result of cooling the inside of the projector. This isn't a product malfunc-

air outlet grilles.

tion.

 

 

No audio is output.

Check that the volume isn't set to low.

 

 

The menu can't be used.

The microcomputers inside the projector may be wrongly operating because of noise.

 

￿ Press the POWER button to turn off the lamp and unplug the power cord from the wall outlet. Wait

 

about 10 minutes, plug the power cord in, and try again.

 

 

"TEMPERATURE!!" is dis-

This indication appears when the ambient temperature rises high. When the ambient tempera-

played.

ture stays high, the lamp goes out.

 

￿ Eliminate any causes of the rise in the ambient temperature.

 

This indication appears when the air inlet or outlet grille is blocked. When they are kept blocked,

 

the lamp goes out.

 

￿ Remove the objects blocking the air inlet or outlet grille.

 

 

The mark appears.

This mark appears when ineffective operation is carried out. This isn't a product malfunction.

 

 

The remote control doesn't

Check that the battery is loaded in the remote control or the battery isn't weak. (See page 8.)

function easily or at all.

Check that the remote control sensor isn't exposed to direct sunlight or fluorescent light. (See

 

page 8.)

 

Use the remote control within its operation range. (See page 8.)

 

Use the remote control at least 10 cm away from the projector.

 

 

The buttons on the control

PASSWORD FUNCTION in the FEATURE menu has been set to MENU ACCESS to enable the

panel (except for the

password lock.

POWER button) don't

￿ Cancel the password lock or contact the person in charge of management of the projector. (See page

function.

25.)

 

 

Abnormal sound is heard.

Because the color wheel spins at a high speed, metalic sounds may be heard in rare occations.

 

Such sympton is not a malfunction.

 

 

ENGLISH

When the problems below occur after the lamp is replaced, check the following.

Problem

Cause and solution

 

 

The power isn't turned

Attach the lamp cover on the bottom correctly.

on.

Reset the lamp operation time. (See page 26.)

The STATUS indicator

Reset the lamp operation time. (See page 26.)

blinks.

 

 

Maintenance

Caution:

Be sure to turn off the lamp and unplug the power cord from the wall outlet before you perform any maintenance on the projector.

Cleaning of the projector and the ventilation slots

Use a soft cloth to clean the projector and the ventilation grilles. When the grilles become dirty, wipe them with a soft cloth dampened with diluted mild detergent, and then wipe them with a dry cloth.

To protect the surface of the projector from fading or deteriorating:

Do not spray insecticide on or inside the projector.

Do not use benzine or thinner to clean it.

Do not let rubber or plastic materials contact with projector.

Cleaning of the lens

Use a standard lens-cleaning brush or a piece of lens tissue dampened with lens cleaning fluid. The lens surface is fragile. Use only recommended, nonabrasive lens-cleaning materials. Do not touch the lens with your fingers.

EN - 29

Page 29
Image 29
Mitsubishi Electronics XD480U user manual Maintenance, Others, Cleaning of the projector and the ventilation slots