Indicators
The projector has three indicators each of which shows the working condition of the projector.
The following offers solutions to possible problems. If a problem persists, turn the projector off and consult your dealer.
TEMP indicator
LAMP indicator
POWER indicator
TEMP LAMP POWER
Normal condition
POWER LAMP | TEMP CONDITION | Notes | |
Steady | Off |
| |
Off |
| ||
red |
|
|
|
|
| Lamp | The power button cannot be used to switch |
Steady | Blinking | Off | OFF. |
green | green |
| |
|
| The POWER is ON. (Normal condition) |
|
Steady | Steady | Off |
|
green | green |
|
|
Abnormal condition
POWER LAMP | TEMP | |
Steady | Steady | Blinking |
green | green | red |
Steady | Off | Blinking |
red |
| red |
CONDITION | POSSIBLE SOLUTIONS |
Unusual temperature | • Remove the object from the ventilation |
• The ventilation slits or air filter is clogged with | |
dust or debris. | slits. |
• The room temperature is too high. | • Relocate the projector to a cooler place. |
• The filter is dirty. | • Clean the filter. |
|
|
|
|
|
|
| The protection circuit is working or the lamp is in an | |
|
|
|
|
|
|
| ||
Steady | Blinking | Off | abnormal condition. | |||||
(The indicators operate as shown on the left at the time of | ||||||||
red | green |
| ||||||
|
|
|
|
|
|
| In this case, they are’nt indicating an abnormal condition.) |
•Wait until the LAMP indicator is turned off, then press the POWER button.
•If the above operation is not effective, replace the lamp.
Lamp duration warning. (Lightning duration total
Steady Blinking Off about 1, 000 hours*.When the POWER is ON.)
green green/red
|
|
|
| Off | Lamp duration warning. (Lightning duration total | |
Steady | Blinking | |||||
about 1, 000 hours*.When the POWER is OFF.) | ||||||
red | red |
|
Replace the lamp.
Exchange with a new lamp if the same problem recurs.
Steady | Steady | Off | Lamp duration warning. (Lightning duration total |
|
about 1,500 hours*.) |
| |||
red | red |
|
| |
|
|
| The lamp or filter cover is not closed. | Close the cover correctly. |
Blinking | Off | Off |
|
|
green/red |
|
|
|
|
| Steady | Steady | Abnormal. | Contact your dealer. |
|
|
| ||
Blinking | or | or |
|
|
|
|
|
| |
green/red |
|
|
|
|
| Blinking | Blinking |
|
|
*) When LAMP MODE of the INSTALLATION menu is set to STANDARD.When it is set to LOW, the duration will be extended.
EN – 26