Mitsubishi Electronics XL650U Indicators, Normal condition, Abnormal condition, English

Models: XL650U

1 45
Download 45 pages 28.58 Kb
Page 35
Image 35
Indicators

Indicators

This projector has 2 indicators, each of which shows the operation condition of the projector.

The following offer solutions to possible problems. If these problems persist, turn the projector off and consult your dealer.

POWER indicator

STATUS indicator

Normal condition

POWER

STATUS

CONDITION

NOTE

Steady

Off

Stand-by

 

 

 

red

 

 

 

Steady

Blinking

Lamp stand-by (about 1 minute)

The POWER button cannot be used to

 

switch between on and off.

green

green

 

Steady

Steady

The power is on. (Normal condition)

 

 

 

green

green

 

 

Abnormal condition

POWER

STATUS

CONDITION

POSSIBLE SOLUTION

 

 

 

 

 

 

 

 

 

 

Abnormal temperature

 

Steady

 

 

 

 

 

• The ventilation grilles are clogged with dust or dirt.

• Clean the ventilation grilles.

green

 

 

 

 

 

• The room temperature is high.

• Relocate the projector to a cooler place.

or

 

 

 

 

 

 

 

Blinking orange

 

 

Steady red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The protection circuit is working or the lamp is in an

• Wait until the STATUS indicator goes out,

Steady red

 

 

 

 

 

abnormal condition.

then press the POWER button.

 

 

 

 

 

Blinking green

 

• If the above solution is not effective,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replace the lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation time

Replace the lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

Blinking green/red

reached 3750 hours*1 while the power was on.)

Change with a new lamp if this problem

green

 

 

 

 

 

 

recurs.

 

 

 

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady red

Blinking red

reached 3750 hours*1 while the power was off.)

 

 

 

 

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation time

 

Steady red

Steady red

reached 5000 hours*1*2 while the power was off.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

The lamp cover isn’t closed.

Close the cover correctly.

 

 

 

 

 

 

Blinking

 

 

 

 

 

 

 

 

 

 

green/red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal.

Contact your dealer.

Steady

or

Blinking

green/red

Blinking

*1 Duration when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be shorted.

*2 Duration when LAMP MODE is set to STANDARD, this duration will be shorted up to 2000 hours.

ENGLISH

EN-35

Page 35
Image 35