Moffat E20M operation manual Installation Requirements

Models: E20M

1 17
Download 17 pages 28.39 Kb
Page 6
Image 6
Installation

Installation

Installation Requirements

Important:

Installation shall comply with local electrical, health and safety requirements.

It is most important that this oven is installed correctly and that oven operation is correct before use.

If you have any questions regarding the proper installation and / or operation of this oven, please contact your local Turbofan distributor.

Unpacking

1.Remove all packaging and transit protection including all protective plastic coating from the exterior stainless steel panels.

2.Check the oven and supplied parts for damage. Report any damage immediately to the carrier and distributor.

3.Check that the following parts have been supplied with your oven:-

4 x Leg Adjustable.

4.Report any deficiencies to the distributor who supplied your oven.

5.Securely fit the 4 legs supplied with the oven.

6.Check that the available electrical supply is correct to that shown on the Technical Data Plate located on the front right hand side panel.

Refer to ‘Specifications’ section, ‘Oven Specifications Tables’.

Location

1.Position the oven in its approximate working position.

2.The unit should be positioned so that the control panel and oven shelves are easily reachable for loading and unloading.

Electrical Power

 

 

Oven

 

Rating

 

Serial Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven

 

Current Draw

 

Model Number

MOFFAT LIMITED

MODEL

E22M3

CHRISTCHURCH ( NEW ZEALAND )

 

CODE

USE22M3

 

SERIAL

xxxxxx

12.0 A @ 115 V a.c.

LOT

*******

 

 

 

1P+N+E 110-120V a.c. 50-60Hz 1.5 kW

THIS APPLIANCE MUST BE EARTHED / GROUNDED

THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH CURRENT

REGULATIONS AND USED ONLY IN A WELL-VENTILATED SPACE. REFER TO THE

INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE.

Technical Data Plate - Data and Location

(example only)

Clearances

To ensure correct ventilation for the motor and controls, the following minimum installation clearances are to be adhered to:-

 

Top

100 mm / 4”.

 

 

Rear

25 mm / 1”.

 

 

Left-hand side

25 mm / 1”.

 

 

Right-hand side

25 mm / 1”.

 

 

 

 

 

 

 

 

 

Important:

The vent located at the top (E22 Ovens) or rear (Other 20 Series Ovens) of the oven must NOT be obstructed.

Oven Vent Location

 

Oven Vent Location

E22 Ovens

 

E23, E27, E28 Ovens

Stand Mounted Oven

For ovens that are to be mounted to a stand, the oven feet are used to level the oven on the stand. Refer to the instructions supplied with separately ordered stands for mounting details.