2.Adjust the oven feet to level the oven.

Installation

Electrical Connection

Warning

This oven must be earthed / grounded.

If the supply cord is damaged, it must be replaced by a suitably qualified person in order to avoid a hazard.

Each oven should be connected to an adequately protected power supply and an isolation switch mounted adjacent to, but not behind the oven and must be readily accessible to the operator. This switch must be clearly marked and readily accessible in case of fire.

Check the electricity supply is correct to as shown on the Technical Data Plate on the front right hand corner of the oven side panel.

Ovens Supplied with Cordsets (E22M3, E23M3, E27M2, E27M3)

1.Ensure that the oven is fitted with the appropriate power cord and plug.

NOTE: For non USA / Canada E27M3 Ovens only, ovens will be supplied with a bare cord only. An appropriate plug must be supplied and fitted by a suitably qualified person.

Ovens Supplied without Cordsets (E28M4).

NOTE: All electrical connections must only be carried out by a suitably qualified person.

Positioning and Levelling of Oven

1.Correctly locate the oven into its final operating position and using a spirit level, adjust the legs so that the oven is level and at the correct height.

2.Adjust the oven feet to level the oven.

Initial Start-Up

Before using the new oven;

1.For first time use of the oven, operate the oven for about 1 hour at 200°C / 400°F to remove any fumes or odours which may be present.

2.Please refer to the Operation Section of this manual for details on how to correctly operate and shutdown the oven.

1.Remove oven rear cover panel.

2.Bring the supply cable up through the grommet at the back of oven and through the compression gland on the electrical switchgear panel.

3.Connect the mains supply to the appropriately marked terminals on the terminal block.

Compression Electrical

Gland Panel

Grommet

NOTE:

Fixed wiring installations must incorporate an all-pole disconnection switch.