Troubleshooting

Trouble

Probable Cause

Remedy

 

 

 

 

Digital display not illuminated.

No Power.

• Check 120 volt power source.

 

 

• Power button has not been depressed.

• Press power button once to turn on.

 

 

 

 

Fan not operating (digital

ROOM humidity level is not 3% or more

• Raise SET humidity level if desired.

display is illuminated).

below SET humidity level.

• Increase fan speed.

 

Reservoir is empty.

• Fill humidifier with water.

 

 

 

 

Fan running continuously,

Float is obstructed.

• Free float from obstruction.

unit will not shut off.

SET humidity level is 65%.

• A SET humidity percentage

 

• ROOM humidity level has not reached 1%

of 65% operates fan

 

 

or more above SET humidity level.

continuously. Adjust SET

 

 

 

level between 25% - 60%.

 

 

 

• Continue to run until desired humidity

 

 

 

level is achieved. This may take up to 48

 

 

 

hours initially.

Poor evaporation of water.

• Check filter message “CF” is flashing.

• Change to a fresh new filter.

 

• Mineral buildup on filter.

NOTE: Local water purity varies from area

 

 

 

to area.

Neither bottle emptying.

Bottle cap plunger missing post in bottom

• Check orientation of bottles.

 

of cabinet.

Reposition so that bottle cap plunger

 

Dirty filters.

(stem) is depressed by post in bottom of

 

 

 

cabinet.

 

 

 

• Change to fresh new filters

 

 

 

(HDC12).

Bottles continues to empty.

Air is entering water bottle.

• Check “Side-Fill Caps” and valve

 

 

 

assembly caps to ensure tightness.

 

 

 

• Check for leak in water bottle.

 

 

 

• Ensure gaskets for “Side-Fill Caps” are in

 

 

 

place.

 

 

 

 

Left bottle not emptying.

Right bottle contains water.

The humidifier is designed so that right

 

 

 

bottle empties first.

Refill display “F” is on before

Unit is not set up on a level surface.

• Position unit level. (Some carpet padding

bottles are empty.

 

(Float will not sense water at the front of

may allow unit to sit lower in the front than

 

 

the cabinet.)

rear with the additional weight of water

 

 

 

bottles in the front of the cabinet. Install

 

 

 

caster pads under front casters (see page

 

 

 

5).

 

 

 

 

Display blinks or fan moves slightly when

Normal.

• No action required.

humidifier is plugged in.

 

 

 

 

 

 

 

Alternating “F” and room humidity displayed.

Reservoir is empty.

• Fill humidifier with water.

 

 

 

 

Alternating “CF” and room humidity

Filter may be dirty.

• Replace filter.

displayed.

 

 

 

 

CAUTION: Use only EPA Registered Bacteriostat.

Use of other water treatment products may damage the filter elements. Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers.