CHECKING GAS PRESSURE AND CONNECTING REMOTE RECEIVER

The heater gas inlet connection is 3/8" NPT at the valve. The

WARNING

 

 

inlet is located on left side of stove. Remove front control plate

Connecting directly to an unregulated

 

to better access the inlet.

 

 

propane/L.P.G. tank can cause an

When tightening up the joint to the valve, hold the valve securely

 

 

explosion.

with a wrench to prevent movement.

 

 

Test all gas joints from the gas meter to the heater valve for

 

 

 

 

leaks using a gas analyzer or soap and water solution after completing connection. DO NOT USE AN OPEN FLAME. Check the gas pressure with the appliance burning and the control set to HIGH.

MILLIVOLT CONTROL (FIGURE 10)

Test Port “OUT”

The valve regulator controls the burner pressure which should be checked at the pressure test point.

If outlet pressure is low, check inlet pressure against data plates or manual.

Turn captured slotted screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point “OUT” closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks.

Figure 10 - Pressure Test Point Location

Milli-Volt Control

NOTE: Remove control panel to access gas valve and ignitor battery module.

CONNECTING REMOTE RECEIVER

1.Remove cover on control panel to show opening for remote receiver. See Figure 11.

2.Cut cable to length (approximately 12") for placement in the fireplace.

3.Strip back 1/4" of the insulation from free end of each wire. Do not cut off wire connector.

4.Connect two .25 female connectors to the wires at free end of the cable.

5.Insert the wire connector into the receiver. If remote does not have plug-in connector, strip back 1/4" of insulation. Insert wire into terminal and tighten screws.

6.Connect the connectors to the two .25" male connectors located on the left side when facing the unit. See Figure 11. Do not let the wire touch the grate or burners.

7.Slide remote receiver in the opening of control panel. Use two screws provided to attach remote receiver to the control panel. See Figure 11.

8.Replace Cover. See Figure 11.

NOTE: Do not place remote in combustion chamber.

Remote Receiver

Cover

Figure 11 - Installing Remote Receiver

58D56002

15

Page 15
Image 15