Monessen Hearth CSVF30SPV Rock Wool Installation, Rock wool depth must not be more than, for LP

Models: CSVF30SPV CSVF20SNV CSVF20SPV CSVF30SNV

1 32
Download 32 pages 9.39 Kb
Page 20
Image 20
ROCK WOOL INSTALLATION

ROCK WOOL INSTALLATION

1.Break rock wool into dime-sized pieces.

2.Place rock evenly across rock wool tray and front burner as shown in Figure 18.

Rock wool depth must not be more than 1".

Do not place rock wool past the bend in rock wool tray.

Do not place rock wool on rear burner.

WARNING

Rock wool must be placed correctly. Placing rock wool in wrong area will create high carbon monoxide.

Bend in Rock

Wool Tray

Rock Wool

Rock Wood

Tray

REMOTECONTROL

 

PILOT

Figure 18 - Rock Wool Installation

OFF

FLAME APPEARANCE

Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation.

CHECKING PILOT FLAME

The pilot flame must always be present when the heater is in operation. It should just touch the top of the ther- mocouple tip for natural. See Figure 19 for correct pilot flame.

If the pilot flame does not touch the thermocouple, then the burners cannot function reliably. See Figure 20 for incorrect shape of pilot flame.

MILLI-VOLT CONTROL

Thermocouple

Thermocouple

for Natural

for Natural

Thermocouple

Thermocouple

for LP

 

for LP

Figure 19 - Correct Appearance of Pilot Flame

Figure 20 - Incorrect Appearance of Pilot Flame

20

58D6002

Page 20
Image 20
Monessen Hearth CSVF30SPV Rock Wool Installation, Rock wool depth must not be more than, Thermocouple, for Natural, for LP